v1.2.0

enhancements

    Antenna pattern manual measurement feature added
    Signal Level Monitor measurement feature added
    Correction tables feature added
    Added user-selectable trace colours to preferences/settings
    Added feature to allow user to create/modify preset types

    Made GUI controls work when tinySA is not connected
    Code changes for PyQt6 with PyQt5 backwards compatibility
    LNB Mode now uses config database and new user-preset types

    Changed waterfall size slider to a show/hide checkbox (unable to fix errors caused by size adjustment) and added auto-range checkbox
    Filled marker on-screen text values background with black
    Set spur combobox default to auto
    Removed some repetitive code into the ModelView class
    Tweaks to dialogue and logging text
    Sub-window updates to make layout of buttons more consistent
    PopUp message function improved
    Linting changes
    Some functions merged into modelview class
    Change to using uic.loadUi instead of needing to create .py files with pyuic
    Improvements to view updates of tables
    * database structure changes *
    Only off-screen markers are set in window if ^ button is pressed
    Frequency precision and units added to fading graphs
    Turning a marker off hides its fading graph
    improved GUI initialisation

fixes

    fixed waterfall index errors by removing resize slider and replacing it with a checkbox to show/hide
    fix issue #113
    fix issue #111
    fix issue #112
    Enhancement #103
    ui bugfix
    nuitka-project pyqt6 bugfix
    fixed auto-update config database
    fixed add row / delete row in preset marker settings
    fixed marker dragging displayed freq
    separated settings and fixed bands/markers screens
    fix shape factor for Phase Noise calculation
    fix database update
    Fixed bug when clicking browse tinySA and is not connected


v1.1.0
?

v0.11.9

Bugfixes
If detected device is not a tinySA, don't crash but log info to terminal

v0.11.8

Bugfixes
Issue 66: preferences still save to the config database if a TinySA is not connected.
Issue 67: file >Browse TinySA shows correct bitmap file and 'save' saves the selected (clicked-on) file.
Fixed trace updates stopping for very fast sweeps.

The single file executables include the config database. If you are upgrading from a version older than v0.11.7, rename the old database first and the new one will be copied automatically.

QtTinySA.bin is a new Linux executable that was built using the 'Nuitka' Python Compiler and works on Ubuntu 24.04 and 22.04 and Debian v12. It does not work on earlier versions.

QtTinySA.exe is a new Windows executable that was built using the 'Nuitka' Python Compiler.

v0.11.7

NOTE: This release requires the updated config database QtTSAprefs.db. It is backwards compatible with firmware older than 1.4.177 as far back as 1.4.120. It does not work with firmware 1.4.109 or earlier.

Much faster stopping on slow sweeps when 'stop' is pressed.
Changed the way the GUI screen is updated by the measurement thread. Previously it was updated every 20 measurements, so the update rate varied and for very fast sweeps could cause the GUI to freeze. Now it is a fixed rate and set in the 'preferences' dialogue in mS and there is a 'update rate indicator' at the bottom left of the main screen.
Changed measurement Fn to use the new scanraw auto-repeat option available with firmware 1.4.177 onwards.
Zero span now working as well as it can without re-coding
Added code for enhancement #58 (detect/choose from several connected tinySA, request by Herb Walker)
Added box to set the maximum scan frequency above 6GHz in 'preferences' dialogue (request by @ashjmckenzie )
Changed 'max' trace to permanent hold until scanning stopped/restarted, instead of a decaying max based on scan 'memory' (request by @CliveTombs)
Marker min/max detection frequency boundary lines added (request by @CliveTombs)
SyncTime, AverageBox & Sample repeat added to config database
Removed padding from the GUI display
Set Scan to Graph button (<>) added
Clicking a marker centres the sweep freq onto that marker
Units on freq axis now set automatically (changed preferences database to Hz instead of MHz)
Changes to openport Fn and testport Fn with error trapping

Bugfix: selecting a marker set freq incorrectly
Bugfix: band selection combobox didn't work unless tinySA hardware was detected
Bugfix: (#56) band add fail after preferences window opened
Bugfix: filebrowse picture not being shown if a csv was selected first
Bugfix: min/max marker Fn
Bugfix: when marker selected in band combo box

Thank you to @CliveTombs for a lot of testing.

v0.11.6
Bugfix: selecting a marker set freq incorrectly
Bugfix: band selection combobox didn't work unless tinySA hardware was detected
Updated preferences database with freqs in Hz instead of MHz

v0.11.4 bugfixes
Fixed band add fail after preferences window opened
Fixed filebrowse picture not being shown if a csv was selected first
removed gui update at end of scan

v0.11.3
backwards compatible with firmware older than 4.177
scanraw auto-repeat code tidied up
changes to openport and testport with error trapping
much faster stopping on slow sweeps
bug #56 still to fix
testing still to do

v0.11.2 wip
auto-repeat scanraw changes

v0.11.1
Fix multiple device detection for pySerial returning no product info in Windows

v0.10.7.n
max hold fixed
zero span working as well as it can without re-coding
selection of device when multiple tinySA tested

v0.10.7m
code for enhancement #58 (more than one device)
fixed various bugs caused by changes
work in progress

v0.10.7i
Changed 'max' trace to permanent hold until scanning stopped/restarted, instead of a decaying max based on scan 'memory'

v0.10.7h
working zero span

v0.10.7g wip
fixed min/max marker Fn
reversed change to averaging as it was defective
fixed span bug when marker selected in band combo box

v0.10.7f wip
marker min/max detection boundary
syncTime, AverageBox & Sample repeat added to config database
trace averaging improvement but more to do
potentially a lot of bugs added

v0.10.7d
Removed padding from display
Set Scan to Graph button added

v0.10.7c
Marker bug fixed
Marker click centres freq on marker

v0.10.7a
improved zero span?
auto units on freq axis